Evaluation systems for PV material by measuring PL lifetime, luminescence quantum yield and membrane thickness.

Compact NIR photoluminescence lifetime spectrometer

Near infrared compact fluorescence lifetime measurement systems

Measuring PL spectrum and PL lifetime of thin film compound semiconductor photovoltaic materials, for example CIGS or CZTS, Which is closely related to conversion efficiency.

Compact NIR PL lifetime spectrometer: C12132-36  NEW

    • Laser class 1 model
    • 580 nm to 1650 nm

    Complies with laser class 1. It can be used outside of a laser controlled area.

    Compact NIR PL lifetime spectrometer: C12132-37  NEW

      • Laser class 3B model
      • 580 nm to 1650 nm

      Complies with laser class 3B. It is upgradable for multipoint measurement with optical fibers.

      Compact NIR PL lifetime spectrometer: C12132-38  NEW

        • Uses an external laser
        • 380 nm to 1650 nm

        Uses an external laser as the excitation light source. Adding the PLP-10 laser diode head as an excitation light source is an option.

        Quantaurus-QY Plus UV-NIR absolute PL quantum yield spectrometer

        UV-NIR Abolute PL quantum yields measurement system Quantaurus-QY Plus

        Compact one-box organic photovoltaic cell material measurement system to measure luminescence quantum yield with easy operation.Additional options allow high-sensitivity, near-infrared, and upconverted measurements.

        Quantaurus-QY Plus UV-NIR absolute PL quantum yield spectrometer: C13534-11

          • Standard type

          Absolute quantum yield spectrometer with detection range from 300 nm to 950 nm and detection resolution less than 2 nm (standard type).

          Quantaurus-QY Plus UV-NIR absolute PL quantum yield spectrometer: C13534-12

            • NIR type

            Absolute quantum yield spectrometer with detection range from 400 nm to 1100 nm and detection resolution less than 2.5 nm (NIR type ).

            Quantaurus-QY Absolute PL quantum yield spectrometer

            Abolute PL quantum yields measurement system Quantaurus-QY

            Compact one-box organic photovoltaic cell material measurement system to measure luminescence quantum yield with easy operation.

            Quantaurus-QY Absolute PL quantum yield spectrometer: C11347-11

              • Standard type

              Absolute quantum yield spectrometer with detection range from 300 nm to 950 nm and detection resolution less than 2 nm (standard type).

              Quantaurus-QY Absolute PL quantum yield spectrometer: C11347-12

                • NIR type

                Absolute quantum yield spectrometer with detection range from 400 nm to 1100 nm and detection resolution less than 2.5 nm (NIR type).

                PMA-12 Photonic Multichannel Analyzer

                Photonic Multichannel Analyzer PMA-12

                EL/PL spectrum multi channel simultaneous measurement system used for chemical compound thin-film photovoltaic cell, such as CIGS that altered by composition ratio.

                PMA-12 Photonic multichannel analyzer: C10027-01

                  • Ultrahigh sensitivity model

                  High sensitivity multichannel analyzer with sensitivity from 200 nm to 950 nm.

                  PMA-12 Photonic multichannel analyzer: C10027-02

                    • Ultrahigh sensitivity model

                    High sensitivity multichannel analyzer with sensitivity from 350 nm to 1100 nm.

                    PMA-12 Photonic multichannel analyzer: C10028-01

                      • Near infrared model

                      NIR sensitivity multichannel analyzer with sensitivity from 900 nm to 1650 nm.

                      PMA-12 Photonic multichannel analyzer: C10028-02

                        • Near infrared model

                        NIR sensitivity multichannel analyzer with sensitivity from 1600 nm to 2350 nm.

                        PMA-12 Photonic multichannel analyzer: C10029-01

                          • High time resolution model

                          High speed gate and high sensitivity multichannel analyzer with sensitivity from 200 nm to 860 nm and gate speed up to 10 ns.

                          PMA-12 Photonic multichannel analyzer: C10544-01

                            • High sensitivity superior cost-performance model

                            High performance and low cost multichannel analyzer with sensitivity from 300 nm to 800 nm.

                            PMA-12 Photonic multichannel analyzer: C10544-02

                              • High sensitivity superior cost-performance model

                              High performance and low cost multichannel analyzer with sensitivity from 340 nm to 830 nm.

                              Absolute PL quantum yield spectrometer

                              Abolute PL quantum yields measurement system

                              Organic photovoltaic cell material evaluation system using luminescence quantum yield measurement. Its short time measurement can be applicable to any sample shapes such as solution, membrane and particles.

                              Absolute PL quantum yield spectrometer: C9920-02G

                                • Automatic control of excitation wavelength

                                Absolute quantum yield spectrometer with detection range from 300 nm to 950 nm and bandwidth from 2 nm to 5 nm FWHM (automatic control of excitation wavelength).

                                Absolute PL quantum yield spectrometer: C9920-03G

                                  • Automatic control of excitation wavelength

                                  Absolute quantum yield spectrometer with detection range from 400 nm to 1100 nm and bandwidth from 2 nm to 5 nm FWHM (automatic control of excitation wavelength).

                                  Optical NanoGauge

                                  Optical NanoGauge

                                  Non-contact high precision membrane thickness measurement systems utilizing optical method.

                                  Optical NanoGauge: C12562-04

                                    • Ultrathin film measurement with high speed
                                    • 0.5 μm to 300 μm

                                    Optical NanoGauge measures film thickness utilizing spectral interferometry. It measures glass from 0.5 μm to 300 μm.

                                    Optical NanoGauge: C13027-12

                                      • Supports PLC connections with high speed
                                      • 10 nm to 100 µm

                                      Optical NanoGauge measures film thickness utilizing spectral interferometry. It not only supports PLC connections but is also designed more compact than our other models for easy installation into equipment.

                                      Go to top

                                      Disclaimer
                                       [66KB/PDF]

                                      The save-to-list function can only work if JavaScript is turned on.

                                      The recently viewed function can only work if JavaScript is turned on.