Fluorescence material evaluation systems for characteristics such as absolute quantum yield, life time of phosphorescence and transient absorption.

Quantaurus-QY Plus UV-NIR absolute PL quantum yield spectrometer

UV-NIR Abolute PL quantum yields measurement system Quantaurus-QY Plus

Compact one-box absolute quantum yield spectrometer for luminescence material using photoluminescence method. Additional options allow high-sensitivity, near-infrared, and upconverted measurements.

Quantaurus-QY Plus UV-NIR absolute PL quantum yield spectrometer: C13534-11

    • Standard type

    Absolute quantum yield spectrometer with detection range from 300 nm to 950 nm and detection resolution less than 2 nm (standard type).

    Quantaurus-QY Plus UV-NIR absolute PL quantum yield spectrometer: C13534-12

      • NIR type

      Absolute quantum yield spectrometer with detection range from 400 nm to 1100 nm and detection resolution less than 2.5 nm (NIR type ).

      Quantaurus-QY Absolute PL quantum yield spectrometer

      Abolute PL quantum yields measurement system Quantaurus-QY

      Compact one-box absolute quantum yield spectrometer for luminescence material using photoluminescence method. Not only thin materials but also liquid solution and powder can be applied. It quickly measures the absolute PL quantum yield, excitation wavelength dependence and PL in short time.

      Quantaurus-QY Absolute PL quantum yield spectrometer: C11347-11

        • Standard type

        Absolute quantum yield spectrometer with detection range from 300 nm to 950 nm and detection resolution less than 2 nm (standard type).

        Quantaurus-QY Absolute PL quantum yield spectrometer: C11347-12

          • NIR type

          Absolute quantum yield spectrometer with detection range from 400 nm to 1100 nm and detection resolution less than 2.5 nm (NIR type).

          Absolute PL quantum yield spectrometer

          Abolute PL quantum yields measurement system

          Absolute quantum yield spectrometer for luminescence material using photoluminescence method. Not only thin materials but also liquid solution and powder can be applied.

          Absolute PL quantum yield spectrometer: C9920-02

            Absolute quantum yield spectrometer with detection range from 300 nm to 950 nm and bandwidth less than 10 nm FWHM (manual control of excitation wavelength).

            Absolute PL quantum yield spectrometer: C9920-02G

              • Automatic control of excitation wavelength

              Absolute quantum yield spectrometer with detection range from 300 nm to 950 nm and bandwidth from 2 nm to 5 nm FWHM (automatic control of excitation wavelength).

              Absolute PL quantum yield spectrometer: C9920-03

                Absolute quantum yield spectrometer with detection range from 400 nm to 1100 nm and bandwidth less than 10 nm FWHM (manual control of excitation wavelength).

                Absolute PL quantum yield spectrometer: C9920-03G

                  • Automatic control of excitation wavelength

                  Absolute quantum yield spectrometer with detection range from 400 nm to 1100 nm and bandwidth from 2 nm to 5 nm FWHM (automatic control of excitation wavelength).

                  Quantaurus-Tau Fluorescence lifetime spectrometer

                  Compact fluorescence lifetime spectromter Quantaurus-Tau

                  Compact one-box fluorescence life time measurement system to measure fluorescence life time and photoluminescence spectrum with easy operation and high precision.

                  Quantaurus-Tau Fluorescence lifetime spectrometer: C11367-31

                    • Standard type

                    Standard model. (Sample: Solution・Thin-film, Wavelength range: 300 nm to 800 nm)

                    Quantaurus-Tau Fluorescence lifetime spectrometer: C11367-32

                      • NIR type

                      NIR model. (Sample: Solution・Thin-film, Wavelength range: 380 nm to 1030 nm)

                      Quantaurus-Tau Fluorescence lifetime spectrometer: C11367-34

                        • Standard type

                        Standard model. (Sample: Solid (Thin-film・Powder), Wavelength range: 300 nm to 800 nm)

                        Quantaurus-Tau Fluorescence lifetime spectrometer: C11367-35

                          • NIR type

                          NIR model. (Sample: Solid (Thin-film・Powder), Wavelength range: 380 nm to 1030 nm)

                          Picosecond fluorescence lifetime measurement system

                          Picosecond fluorescence lifetime measurement system

                          High sensitivity and high time resolution (5 ps) fluorescence life time measurement system utilizing 2-D photon counting method to measure multi-spectrum fluorescence life time.

                          Picosecond fluorescence lifetime measurement system: C11200 / Mode-locked laser system

                            • For mode-locked Ti-Sapphire laser

                            Fluorescence lifetime measurement system with mode locked Ti-Sapphire laser. It realizes maximum sweep frequency of 20 MHz and time resolution of 5 ps.

                            Picosecond fluorescence lifetime measurement system: C11200 / Nitrogen-laser system

                              • For nitrogen-laser-pumped dye laser

                              Fluorescence lifetime measurement system with nitrogen laser-pumped dye laser. It realizes maximum sweep frequency of 10 MHz and time resolution of 100 ps.

                              Picosecond fluorescence lifetime measurement system: C11200 / PLP system

                                • For PLP-10

                                Fluorescence lifetime measurement system with picosecond light pulser. It realizes maximum sweep frequency of 20 MHz and time resolution of 10 ps.

                                Compact NIR photoluminescence lifetime spectrometer

                                Near infrared compact fluorescence lifetime measurement systems

                                The near infrared compact fluorescence lifetime measurement system is designed for measuring photoluminescence (PL) spectrum and PL lifetime in the NIR region.

                                Compact NIR photoluminescence lifetime spectrometer: C12132-16  NEW

                                  • Laser class 1 model
                                  • up to 1650 nm

                                  Complies with laser class 1. It can be used outside of a laser controlled area.

                                  Compact NIR photoluminescence lifetime spectrometer: C12132-17  NEW

                                    • Laser class 3B model
                                    • up to 1650 nm

                                    Complies with laser class 3B. It is upgradable for multipoint measurement with optical fibers.

                                    Compact NIR photoluminescence lifetime spectrometer: C12132-11

                                      • Laser class 1 model
                                      • up to 1400 nm

                                      Complies with laser class 1. It can be used outside of a laser controlled area.

                                      Compact NIR photoluminescence lifetime spectrometer: C12132-12

                                        • Laser class 3B model
                                        • up to 1400 nm

                                        Complies with laser class 3B. It is upgradable for multipoint measurement with optical fibers.

                                        Time-resolved absorption spectrum analysis system

                                        Time-resolved absorption spectrum analysis system

                                        Time-resolved absorption spectrum measurement system to measure transient absorption in the time region from picosecond to nanosecond. Multi-spectrum measurement of irreversible reaction is realized using single shot mode.

                                        Time-resolved absorption spectrum analysis system: Nanosecond system

                                          • For nanosecond range

                                          Time-resolved absorption spectrum analysis system for nanosecond range with time resolution of 7 ns at measurement time from 20 ns to 1 ms.

                                          Time-resolved absorption spectrum analysis system: Picosecond system

                                            • For picosecond range

                                            Time-resolved absorption spectrum analysis system for picosecond range with time resolution of 70 ps at measurement time from 0.5 ns to 20 ms.

                                            Flash photolisis system

                                            Flash photolisis system

                                            System to measure transient absorption spectrum and time-resolved fluorescence spectrum in the time region from nanosecond to millisecond with simultaneous measurement of 260 nm to 800 nm.

                                            Flash photolysis system

                                              • ns to ms
                                              • Transient absorption

                                              Flash photolysis system to perform transient absorption spectrum measurements.