Measurement systems of multispectrum kinetic changes at high sensitivity and high time resolution.

Quantaurus-Tau Fluorescence lifetime spectrometer

Compact fluorescence lifetime spectromter Quantaurus-Tau

Compact one-box fluorescence lifetime measurement system to measure fluorescence lifetime and photoluminescence spectrum with easy operation and high precision.

Quantaurus-Tau Fluorescence lifetime spectrometer: C11367-31

    • Standard type

    Standard model. (Sample: Solution・Thin-film, Wavelength range: 300 nm to 800 nm)

    Quantaurus-Tau Fluorescence lifetime spectrometer: C11367-32

      • NIR type

      NIR model. (Sample: Solution・Thin-film, Wavelength range: 380 nm to 1030 nm)

      Quantaurus-Tau Fluorescence lifetime spectrometer: C11367-34

        • Standard type

        Standard model. (Sample: Solid (Thin-film・Powder), Wavelength range: 300 nm to 800 nm)

        Quantaurus-Tau Fluorescence lifetime spectrometer: C11367-35

          • NIR type

          NIR model. (Sample: Solid (Thin-film・Powder), Wavelength range: 380 nm to 1030 nm)

          Picosecond fluorescence lifetime measurement systems

          Picosecond fluorescence lifetime measurement system

          High sensitivity and high time resolution (5 ps) fluorescence lifetime measurement system utilizing 2D photon counting method to measure multispectrum fluorescence lifetime.

          Picosecond fluorescence lifetime measurement system: C11200 / Mode-locked laser system

            • For mode-locked Ti-Sapphire laser

            Fluorescence lifetime measurement system with mode locked Ti-Sapphire laser. It realizes maximum sweep frequency of 20 MHz and time resolution of 5 ps.

            Picosecond fluorescence lifetime measurement system: C11200 / Nitrogen-laser system

              • For nitrogen-laser-pumped dye laser

              Fluorescence lifetime measurement system with nitrogen laser-pumped dye laser. It realizes maximum sweep frequency of 10 MHz and time resolution of 100 ps.

              Picosecond fluorescence lifetime measurement system: C11200 / PLP system

                • For PLP-10

                Fluorescence lifetime measurement system with picosecond light pulser. It realizes maximum sweep frequency of 20 MHz and time resolution of 10 ps.

                Compact NIR PL lifetime spectrometer

                c12132-36 product photo

                The compact NIR PL lifetime spectrometer is designed for measuring photoluminescence (PL) spectrum and PL lifetime in the NIR region.

                Compact NIR PL lifetime spectrometer: C12132-36  NEW

                  • Laser class 1 model
                  • 580 nm to 1650 nm

                  Complies with laser class 1. It can be used outside of a laser controlled area.

                  Compact NIR PL lifetime spectrometer: C12132-37  NEW

                    • Laser class 3B model
                    • 580 nm to 1650 nm

                    Complies with laser class 3B. It is upgradable for multipoint measurement with optical fibers.

                    Compact NIR PL lifetime spectrometer: C12132-38  NEW

                      • Uses an external laser
                      • 380 nm to 1650 nm

                      Uses an external laser as the excitation light source. Adding the PLP-10 laser diode head as an excitation light source is an option.

                      Time-resolved absorption spectrum analysis systems

                      Time-resolved absorption spectrum analysis system

                      Time-resolved absorption spectrum measurement system to measure transient absorption in the time region from picoseconds to nanoseconds. Multispectrum measurement of irreversible reaction is realized using single shot mode.

                      Time-resolved absorption spectrum analysis system: Nanosecond system

                        • For nanosecond range

                        Time-resolved absorption spectrum analysis system for nanosecond range with time resolution of 7 ns at measurement time from 20 ns to 1 ms.

                        Time-resolved absorption spectrum analysis system: Picosecond system

                          • For picosecond range

                          Time-resolved absorption spectrum analysis system for picosecond range with time resolution of 70 ps at measurement time from 0.5 ns to 20 ms.

                          Flash photolysis systems

                          Flash photolisis system

                          System to measure transient absorption spectrum and time-resolved fluorescence spectrum in the time region from nanoseconds to milliseconds with simultaneous measurement of 260 nm to 800 nm.

                          Flash photolysis system

                            • ns to ms
                            • Transient absorption

                            Flash photolysis system to perform transient absorption spectrum measurements.