LIGHTNINGCURE LC-L5G

GA-107

The GA-107 is capable of irradiating to large samples in one batch.

It contributes reduction of running cost, as an alternative to UV ovens.

Specifications

Parameter L13344-1104 Unit
Light emission window size 107 × 108 mm
Wavelength 365 nm
UV irradiance (*1) at distance of 10 mm (*2) 1.5 W/cm2
LED design life (*3) 20 000 h
Input voltage (DC) +50 V
Power consumption (Max.) Max. 1100 W
Cooling method Forced air cooling by fan
Operating temperature range +5 ℃ to +40 ℃
Storage temperature range -10 ℃ to +60 ℃ (no freezing)
Operating humidity range 20 % to 80 % (no condensation)
Storage humidity range Below 80 % (no condensation)
External control Irradiation control, light intensity adjustment, irradiation signal, various error signals
Connectable operation (*4)
Applicable standard EMC standard IEC 61326-1
Emission limits: CISPR 11 Group 1 Class B
Immunity requirements: Table 2

*1: UV irradiance within the irradiation area.

*2: We recommend to keep 10 mm or more of distance.

*3: Average time until the irradiance drops to 50 % of the initial level when operated at 25 ℃.

*4: Optically connected operation. The light source for cascade operation is designed to minimize degradation of light output at the connected portion when light source is aligned with no gap.

Characteristics

Simulation of irradiance distribution (Typ.)

Light emission window size: 107 mm

Dimensional outline (unit: mm)

 

 

External control connector
(15-pin D-sub) connection

Pin No. Signal
A1 Input voltage (+50 V) Input
A2 GND.
1 No connection
2 No connection
3 GND.
4 Connection confirmation
5 Connection confirmation
6 EMGCY Input
7 GND.
8 Output voltage (+5 V) Output
9 GND.
10 Irradiation control signal Input
11 Light intensity adjustment voltage Input
12 GND.
13 Irradiation signal Output
14 Error signal Output
15 Alarm signal Output